What's the differency between GFCI receptacle and conventional receptacles? ●In the event of a ground fault,GFCI receptacle will trip and quickly stop the flow of electricity to prevent serious injury.
What are the characteristics of GFCI? ■Self-test function Automatic self-test every 1-10 minutes to make sure it can respond to a ground fault ■Weather resistant outdoor GFCI WR GFCI outlet suitable for humid and outdoor environment like bathroom/kitchen/balcony ■Tamper resistant receptacle Tamper resistant devices can prevent children or other unexpected operation from electric shock to maintain a safe environment ■Quality assurance UL listed,every receptacle outlet is individually tested before it leaves the factory assuring buying confidence and trouble free operation for years to come. ■Indicator Light & Alarm Light Indicator light will be on green during operation; Alarm light will be on red Will flash when self-testing and will turn on immediately when GFCI is no longer provide ground fault circuit protection
☛Caution To prevent severe shock or electrocution, always turn the power off at the service panel before working with wiring. Use this GFCI receptacle with copper or copper-clad wire. Do not use it with aluminum wire
Features & details
√ 15amp WR electrical white duplex ground fault circuit interrupter outlet included LED indicator,white decor wall plates and screws, provide continuous ground fault protection √ Weather resistant outdoor GFCI,15amp WR GFCI outlet suitable for humid and outdoor environment like bathroom/kitchen/balcony,UL listed-meets and exceeds UL943 standard,quality assurance √ Tamper resistant receptacle,Tamper resistant devices can prevent children or other unexpected operation from electric shock because of using any foreign body to contact any alive parts of the receptacle from GFCI outlets to maintain a safe environment √ Self-test function,GFCI outlet conducts automatic self-test every 1-10 minutes to ensure integrity of GFCI protection,the device will trip if no ground-fault protection is detected √ LED indicator: Green LED indicator should always be on. When the LED indicator go out,represents a failure in GFCI,when the red LED light is on during use, it reminds you that the outlet is reaches end-of-life and should be replaced
EAN: 0736950899103
Manufacturer: VERSAF
Brand: VERSAF
We hope you love the products we recommend! All of products are independently selected by deal-dx editors. Just to let you know, deal-dx may collect a share of sales or other compensation from the links on this page if you decide to shop from them. As an Amazon Associate we earn from qualifying purchases. Prices are accurate and items in stock as of time of publication.
This website uses cookies for the correct display and functionality. Do you also want to take full advantage of the website and accept cookies? About cookies. Accept cookies